This is Electrochemical sensor for Carbon disulfide.(Electrochemical Carbon disulfide sensor).
Normal detection range:0~3ppm,0~5ppm,0~10ppm,0~8ppm,
0~20ppm,0~30ppm,0~100ppm,0~200ppm,0~300ppm,0~1000ppm,0~10000ppm
Special detection range can be customized.
The Carbon disulfide sensor Modules are available too.
Size: ready stock for all 4 series. 7 series are produced according to orders.
SCIENOC's Carbon disulfide sensor is very stable in normal circumstance for more than 6 months, and can detect Carbon disulfide with excellent accuracy and fast response speed without reduction of sensitivity.standard warranty is 18 months from dispatch time.extended warranty sensors can be customized.
SCIENOC's Electrochemical Carbon disulfide sensor can be retrofitted easily to existing product designs.
Dimensions in millimeters(±0.1mm)
Target Gas and Concentration
Gas | Operating Principle | P/N | Detection Range |
Carbon disulfide (CS2) |
3-electrode electrochemical | EC-4CS2-3 | 0~3 ppm 10 ppm |
EC-4CS2-5 | 0~5 ppm 10 ppm | ||
EC-4CS2-10 | 0~10 ppm 10 ppm | ||
EC-4CS2-20 | 0~20 ppm 10 ppm | ||
EC-4CS2-30 | 0~30 ppm 10 ppm | ||
EC-4CS2-100 | 0~100 ppm 10 ppm | ||
EC-4CS2-200 | 0~200 ppm 10 ppm | ||
EC-4CS2-300 | 0~300 ppm 10 ppm | ||
EC-4CS2-1000 | 0~1000 ppm | ||
EC-4CS2-10000 | 0~10000 ppm |
Gas Sensitivity Characteristics
P/N | Sensitivity | Response Time (T90) | Resolution |
EC-4CS2-3 | 2.0 ± 0.5 mA/ppm | <60s | 0.02 ppm |
EC-4CS2-5 | 2.0 ± 0.5 mA/ppm | <60s | 0.02 ppm |
EC-4CS2-10 | 2.0 ± 1.0 mA/ppm | <50s | 0.1 ppm |
EC-4CS2-20 | 1.2 ± 0.5 mA/ppm | <50s | 0.2 ppm |
EC-4CS2-30 | 1.0 ± 0.5 mA/ppm | 50s | 0.2 ppm |
EC-4CS2-100 | 0.40 ± 0.15 mA/ppm | <60s | 0.1 ppm |
EC-4CS2-200 | 0.20 ± 0.08 mA/ppm | <60s | 0.1 ppm |
EC-4CS2-300 | 0.10 ± 0.5 mA/ppm | <60s | 0.3 ppm |
EC-4CS2-1000 | 40 ± 15 nA/ppm | <60s | 1 ppm |
EC-4CS2-10000 | 4 ± 2 nA/ppm | <60s | <100 ppm |
Ratings & environment
Repeatability | <±2% signal |
Linearity | Linear |
Long term output Drift | <2% signal/month |
Recommended Load | 5~50 Ω |
Bias Voltage | 300 mV |
Operating Temp. Range | -20°C ~ 50°C |
Operating Humidity | 15% RH ~ 90% RH(non-condensing) |
Operating Pressure Range | 800 ~ 1200 mbar |
Storage & Shelf Life
Recommended Storage Temperature | 0℃~ +20℃ in sealed package |
Expected Operating Life | 24 months in air |
Storage Life | 6 months in original package |
Standard Warranty | 18 months from the date of delivery |