YOUR EXPERT IN CHEMISTRY

Acrylonitrile sensor

CAS NO. 107-13-1

Product Code: EC-4CH2CHCN

Acrylonitrile sensor

This is Electrochemical sensor for Acrylonitrile (Electrochemical Acrylonitrile sensor).

Normal detection range:0~1ppm,0~2ppm,0~5ppm,0~8ppm,

0~10ppm,0~20ppm,0~30ppm,0~100ppm,0~50000ppm,

Special detection range can be customized.

The Acrylonitrile sensor Modules are available too.

 

Size: ready stock for all 4 series. 7 series are produced according to orders.

 

SCIENOC's Acrylonitrile sensor is very stable in normal circumstance for more than 6 months, and can detect Acrylonitrile with excellent accuracy and fast response speed without reduction of sensitivity.standard warranty is 18 months from dispatch time.extended warranty sensors can be customized.


SCIENOC's Electrochemical Acrylonitrile sensor can be retrofitted easily to existing product designs.                    

 

Dimensions in millimeters(±0.1mm)      

 

 

 

Target Gas and Concentration

Gas

Operating Principle

P/N

Detection Range

 

 







Acrylonitrile

(CH2CHCN)

 

 







3-electrode

electrochemical

EC-4CH2CHCN-1

0~1 ppm


EC-4CH2CHCN-2

0~2 ppm


EC-4CH2CHCN-5

0~5 ppm


EC-4CH2CHCN-8

0~8 ppm


EC-4CH2CHCN-10

0~10 ppm


EC-4CH2CHCN-20

0~20 ppm


EC-4CH2CHCN-30

0~30 ppm


EC-4CH2CHCN-100

0~100 ppm


EC-4CH2CHCN-50000

0~50000 ppm

                        

Gas Sensitivity Characteristics 

P/N

Sensitivity

Response Time (T90)

Resolution

EC-4CH2CHCN-1

2000 ± 1000 nA /ppm

50 s

0.01 ppm

EC-4CH2CHCN-2

1500 ± 500 nA /ppm

50 s

0.02 ppm

EC-4CH2CHCN-5

1500 ± 500 nA /ppm

70 s

0.05 ppm

EC-4CH2CHCN-8

1200 ± 200 nA /ppm

80 s

0.05 ppm

EC-4CH2CHCN-10

800 ± 200 nA /ppm

70 s

0.1 ppm

EC-4CH2CHCN-20

0.5 ± 0.2 μA /ppm

100 s

0.5 ppm

EC-4CH2CHCN-30

0.40 ± 0.2 μA /ppm

100 s

0.3 ppm

EC-4CH2CHCN-100

100 ± 20 nA /ppm

100 s

0.5 ppm

EC-4CH2CHCN-50000

1 ± 0.5 nA /ppm

100 s

500 ppm

 

Ratings & environment

Repeatability

<±2% signal

Linearity

Linear

Long term output Drift 

<2% signal/month

Recommended Load

5~30 Ω

Bias Voltage

300 mV

Operating Temp. Range

-20°C ~ 50°C

Operating Humidity

15% RH ~ 90% RH(non-condensing)

Operating Pressure Range

800 ~ 1200 mbar

 

Storage & Shelf Life

Recommended Storage Temperature

0℃~ +20℃ in sealed package

Expected Operating Life

24 months in air

Storage Life

6 months in original package

Standard Warranty

18 months from the date of delivery

 

Cross-Sensitivity Data

Available upon request.


Temperature Data

Available upon request

 

Sensitivity Temperature Dependence

Available upon request

 


 

 




Related Keywords: Acrylonitrile sensor,Acrylonitrile sensor module,gas sensor module,Electrochemical sensor for Acrylonitrile,Electrochemical Acrylonitrile sensor,4 ser